karen@brightsparkelectrician.co.uk

01892 531 728

kitchen dining room

Inspections & Testing

When people require their electrics to be checked, they often call it different things:

What they are asking for in all these cases is an in-service, inspection and more importantly Test of their Electrical installation. This is known as only one thing in the IEE wiring regulations - a Electrical Installation Condition Report.

The IEE Wiring Regulations recommend that an Electrical Installation Condition Report should be considered for the following reasons:

  • A change of occupancy of the premises.
  • A change of use of the premises.
  • After alterations or additions to the original installation.
  • Where there is reason to believe that damage may have been caused to the installation.

The title for the Test Report Changed in 2014 under updated IEE Electrical Regulations.  It is now called an "Electrical Installation Condition Report"  (EICR) -it is aptly named as that is what it is, it gives the findings of an Electrical Installation which has been tested - It is NOT a Safety Certificate. Where works are carried out after the EICR to bring the installation up to a safe standard, then the report will give evidence of a satisfactory Installation.

What happens when an Inspection and test is carried out?

A series of visual checks ae carried out on the electrical installation.  Circuit breaker will be checked to ensure they are of the correct type and rating to protect the outgoing cable. The cables will be checked for current carrying capacity and voltage drop. Signs of damage, burning etc., will be looked for. 10% of all sockets, switches etc., are opened up and inspected. If there are any non-compliances found, then even more and probably all of the accessories are then checked.

The Inspection is followed by the tests. 100% of the installation is tested. Several electrical measurements are recorded on the report including continuity of circuit protective conductors, main and supplementary earth bonding, continuity of ring final circuit conductors, insulation resistance, polarity, earth-fault loop impedance, RCD tests including trip time in milliseconds, correct operation of switches, and isolators, protective fault current.

The installation is then declared Satisfactory or Unsatisfactory. Many installations are found to be satisfactory, but are to older regulations, and would benefit from being upgraded. If this is the case then we would advise you of the best way to comply with current standards.

Rates & Fixed Prices

Our Pricing & Rates are Transparent to all Customers. Please see Pricing

For further Information, please do not hesitate to contact us.

Telephone: 01892 531728

Email: karen@brightsparkelectrician.co.uk

"I have had Bright Sparks at my property twice in the last six months to complete some electrical work. I have been blown away by the innovative efficient way I am communicated with the efficiency and ease of the process. The work has been carried out to a more than satisfactory standard and I found it to be extremely competitively priced. It is by far the best experience I have had with any service provider in forever. Thanks guys."

Andrea - Sevenoaks

A rapid response An item of household electrical equipment decided to fail. As a result, many electrical circuits in my Home closed down. I contacted Bright Sparks, and an electrician quickly appeared. He calmly checked the circuits and solve the problems. Well done.

AH - Tonbridge

Thank you for sending us Phil to restore light to all corners of our home. Most agreeable and efficient gentleman who didn't flinch visibly at the dusty mysterious corners where ancient wires lay in ceiling space and appliances wired from the dark ages.

"Miss Moneypenny" - Lamberhurst

Just to say a big thank you for the work that your electrician carried out at my mothers house. He was very professional and a clean worker and the finished job was a complete success. It is very comforting to know that when a tradesperson attends the property of a elderly customer that they feel safe and happy. Once again, Thanks Keith

Keith, Pembury

This company was recommended by some people on the Nextdoor website. I wanted new lights installed in my kitchen, dining room and conservatory. Karen got back to me within minutes of my email and both Electricians proved to be efficient, friendly and tidy workmen. I will be keeping their business card handy for future use.

Jacqueline, Penshurst

REQUEST QUOTE