karen@brightsparkelectrician.co.uk

01892 531 728

kitchen dining room

Inspections & Testing

When people require their electrics to be checked, they often call it different things:

What they are asking for in all these cases is an in-service, inspection and more importantly Test of their Electrical installation. This is known as only one thing in the IEE wiring regulations - a Electrical Installation Condition Report.

The IEE Wiring Regulations recommend that an Electrical Installation Condition Report should be considered for the following reasons:

  • A change of occupancy of the premises.
  • A change of use of the premises.
  • After alterations or additions to the original installation.
  • Where there is reason to believe that damage may have been caused to the installation.

The title for the Test Report Changed in 2014 under updated IEE Electrical Regulations.  It is now called an "Electrical Installation Condition Report"  (EICR) -it is aptly named as that is what it is, it gives the findings of an Electrical Installation which has been tested - It is NOT a Safety Certificate. Where works are carried out after the EICR to bring the installation up to a safe standard, then the report will give evidence of a satisfactory Installation.

What happens when an Inspection and test is carried out?

A series of visual checks ae carried out on the electrical installation.  Circuit breaker will be checked to ensure they are of the correct type and rating to protect the outgoing cable. The cables will be checked for current carrying capacity and voltage drop. Signs of damage, burning etc., will be looked for. 10% of all sockets, switches etc., are opened up and inspected. If there are any non-compliances found, then even more and probably all of the accessories are then checked.

The Inspection is followed by the tests. 100% of the installation is tested. Several electrical measurements are recorded on the report including continuity of circuit protective conductors, main and supplementary earth bonding, continuity of ring final circuit conductors, insulation resistance, polarity, earth-fault loop impedance, RCD tests including trip time in milliseconds, correct operation of switches, and isolators, protective fault current.

The installation is then declared Satisfactory or Unsatisfactory. Many installations are found to be satisfactory, but are to older regulations, and would benefit from being upgraded. If this is the case then we would advise you of the best way to comply with current standards.

Rates & Fixed Prices

Our Pricing & Rates are Transparent to all Customers. Please see Pricing

For further Information, please do not hesitate to contact us.

Telephone: 01892 531728

Email: karen@brightsparkelectrician.co.uk

We have been very impressed by Bright Spark Electrical Services. Karen Smith visited us to discuss our requirements and gave advice which cut our costs. The work was carried quickly and on time with excellent results. The areas affected were clean and tidy when the work was completed. We had a slight problem with a unit but it was dealt with as soon as it was reported. I have no hesitation in recommending this company and will definitely contact them again for any further electrical problems.

Peter W, Paddock Wood

I’d like to say a huge thank you Karen, to you & your team for providing the excellent service you do. Always there when we have an issue or just routine work needs to be carried out. It’s so reassuring that we can rely on you at any time, even for advice. Always professional, knowledgeable & particularly personable Superb…

Kerry, Tunbridge Wells

…. just to say how pleased I have been with the service we have received from Bright Sparks. I have arranged many quotes for work to the property over the past 3 years and your company has consistently returned my calls and emails in a timely way which is much appreciated. You have provided knowledgeable, friendly advice about the work that needed to be done and offered well priced quotes. The work has been completed quickly to a high standard. I'd definitely recommend you to others. Thank you.

Wendy, Broadwater Down

We were very pleased with the recent electrical work which was carried out in a professional manner by your electrician and will certainly use your company again when future needs arise. Also I would be happy to recommend your services to any of our friends.

Tony, Tunbridge Wells

Karen was amazing I can not recommend her highly enough she went over and above my expectations and was indeed a bright spark to my day and helped with love ❤

Landlady - Groombridge

REQUEST QUOTE