Inspections & Testing

When people require their electrics to be checked, they often call it different things:

What they are asking for in all these cases is an in-service, inspection and more importantly Test of their Electrical installation. This is known as only one thing in the IEE wiring regulations - a Electrical Installation Condition Report.

The IEE Wiring Regulations recommend that an Electrical Installation Condition Report should be considered for the following reasons:

  • A change of occupancy of the premises.
  • A change of use of the premises.
  • After alterations or additions to the original installation.
  • Where there is reason to believe that damage may have been caused to the installation.

The title for the Test Report Changed in 2014 under updated IEE Electrical Regulations.  It is now called an "Electrical Installation Condition Report"  (EICR) -it is aptly named as that is what it is, it gives the findings of an Electrical Installation which has been tested - It is NOT a Safety Certificate. Where works are carried out after the EICR to bring the installation up to a safe standard, then the report will give evidence of a satisfactory Installation.

What happens when an Inspection and test is carried out?

A series of visual checks ae carried out on the electrical installation.  Circuit breaker will be checked to ensure they are of the correct type and rating to protect the outgoing cable. The cables will be checked for current carrying capacity and voltage drop. Signs of damage, burning etc., will be looked for. 10% of all sockets, switches etc., are opened up and inspected. If there are any non-compliances found, then even more and probably all of the accessories are then checked.

The Inspection is followed by the tests. 100% of the installation is tested. Several electrical measurements are recorded on the report including continuity of circuit protective conductors, main and supplementary earth bonding, continuity of ring final circuit conductors, insulation resistance, polarity, earth-fault loop impedance, RCD tests including trip time in milliseconds, correct operation of switches, and isolators, protective fault current.

The installation is then declared Satisfactory or Unsatisfactory. Many installations are found to be satisfactory, but are to older regulations, and would benefit from being upgraded. If this is the case then we would advise you of the best way to comply with current standards.

Rates & Fixed Prices

Our Pricing & Rates are Transparent to all Customers. Please see Pricing

For further Information, please do not hesitate to contact us.

Telephone: 01892 531728

Email: karen@brightsparkelectrician.co.uk

I was very pleased with the prompt and efficient service. The electrician phoned in advance to confirm his time of arrival and was friendly and polite.

SM, Leigh

Karen and her team of electricians did a very good job in assessing our electrical circuits, modernising and upgrading our fuse boxes and ensuring compliance with the latest regulations. They were efficient and polite and, when they had finished the work, left the house tidy and in good condition

Robert, St Johns, Tunbridge Wells

Wonderful Job - Thank you very much

Daphne - Lamberhurst

I've used Electricians from Bright Spark 3 times to date , inc. a for a test certificate prior to buying my property. At all times the Electricians have provided a first class service with easy to understand advice and the work completed to a high standard. Many thanks to Karen and the Team.SC

SC - Cranbrook

We have been very impressed by Bright Spark Electrical Services. Karen Smith visited us to discuss our requirements and gave advice which cut our costs. The work was carried quickly and on time with excellent results. The areas affected were clean and tidy when the work was completed. We had a slight problem with a unit but it was dealt with as soon as it was reported. I have no hesitation in recommending this company and will definitely contact them again for any further electrical problems.

Peter W, Paddock Wood

REQUEST QUOTE